Skype ID: unitechbdsoft
Location | 325 Delaware Ave, Buffalo, NY 14202 |
Size | 13,000 square feet |
Commissioned | 2014 |
Utility Power Capacity | 1.44 MW |
Generator Capacity | 11 MW |
Network | XO Communications, TeliaSonera, Hibernia Atlantic |
Network Capacity | 120 Gbps |
Cooling Capacity | 130 Tons total cooling capacity |
Security | Electronic monitoring of security and environmentals; Biometric + Card access security controls |
Location | 101 Possumtown Rd., Piscataway Township, NJ 08854 |
Size | 360,000 square feet |
Commissioned | 2010 |
Utility Power Capacity | 36.4 MW Power Feed |
Generator Capacity | 32 x diesel-powered @ 2.25 MW Capacity Each |
Backup Batteries (UPS) | 32 x Rotary UPS Systems; 1300 KW Each |
Cooling Capacity | 16 x 1,080 Ton centrifugal chillers • 1,000,000 gallon chilled water storage |
Security | Electronic monitoring of security and environmentals; Biometric + Card access security controls |
Location | 2200 Busse Road, Elk Grove Village, IL 60007 |
Size | 485,000 square feet gross; 460,000 square feet of raised floor datacenter space |
Commissioned | 2008 |
Utility Power Capacity | 36.4 MW |
Generator Capacity | 32 diesel-powered @ 2.25 MW each |
Redundancy | 100% Redundant |
Network Capacity | 80 Gbps |
Cooling Capacity | 16 x 1,150 ton centrifugal chillers + 1 million gallon chilled water storage for 24 minutes of continuous full load operation |
Security | 24/7/365 electronic monitoring, secure entry and exit with staffing of at least 2 officers. |
Location | 34 Peachtree Street, Atlanta GA 30303 |
Size | 10,000 SQ Feet |
Commissioned | 2014 |
Utility Power Capacity | 1.6 MW |
Generator Capacity | 1 MW |
Redundancy | 100% Redundant |
Network | 2XO Communications, TeliaSonera, Hibernia Atlantic |
Network Capacity | 20 Gbps |
Cooling Capacity | 234 Tons |
Security | 24/7/365 electronic monitoring. Biometric Card access to datacenter facility provides another layer of security. |
Location | 3000 Irving Blvd., Dallas, TX 75247 |
Size | 68,000 square feet gross; 64,000 square feet of raised-floor datacenter space. |
Commissioned | 2000 |
Utility Power Capacity | 11.1 MW |
Generator Capacity | 6x diesel powered, 2 MW capacity each |
Redundancy | 100% Redundant |
Network Capacity | 20 Gbps |
Cooling Capacity | Fully Redundant HVAC System with roof mounted condensers. |
Security | 24/7/365 electronic monitoring, secure entry and exit. |
Location | 12201 Tukwila International Blvd, Seattle, WA 98168 |
Size | 18,000 square feet colocation space |
Commissioned | 2010 |
Utility Power Capacity | 10 MW Power |
Generator Capacity | 15 x diesel-powered - 1 MW Capacity Each |
Network | ColoCrossing's network consists of redundant connections to WowRack. Additional carriers are onsite and available. |
Network Capacity | 10 Gbit/s Capacity |
Cooling Capacity | 9500+ Tons capacity |
Security | Electronic monitoring of security and environmentals • Biometric + Card access security controls |
Location | 530 W. 6th Street, Suite 901, Los Angeles, CA 90014 |
Size | 50,000 square feet of datacenter floor space |
Commissioned | 2014 |
Utility Power Capacity | 27 MW, expandable to 34 MW |
Generator Capacity | Eight (8) 150 kw and three (3) 2000 kw |
UPS Redundancy | N, 2N, N+1 |
Cooling Redundancy | N+1 |
Fiber and Building Entry | Two (2) underground conduit entry points |
Security | 24x7 onsite Security. 2-Factor authentication with biometric access, CCTV monitoring. |
Location | 55 S. Market Street, San Jose, CA 95113 |
Size | 309,000 square feet |
Commissioned | 1996 |
Utility Power Capacity | 10 MW Power |
Generator Capacity | 1 MW Capacity Each |
Network | EGI Networks, and additional networks and carriers are available onsite. |
Network Capacity | 10 Gbit/s Capacity |
Cooling Capacity | 200+ Tons capacity |
Security | 24/7/365 electronic monitoring, secure entry and exit. |